Diagn Microbiol Infect Dis ; 102(2): 115591, 2022 Feb.
Article in English | MEDLINE | ID: covidwho-1596631

ABSTRACT

Testing for SARS-CoV-2 in resource-poor settings remains a considerable challenge. Gold standard nucleic acid tests are expensive and depend on availability of expensive equipment and highly trained laboratory staff. More affordable and easier rapid antigen tests are an attractive alternative. This study assessed field performance of such a test in western Kenya. We conducted a prospective multi-facility field evaluation study of NowCheck COVID-19 Ag-RDT compared to gold standard PCR. Two pairs of oropharyngeal and nasopharyngeal swabs were collected for comparative analysis. With 997 enrolled participants the Ag-RDT had a sensitivity 71.5% (63.2-78.6) and specificity of 97.5% (96.2-98.5) at cycle threshold value <40. Highest sensitivity of 87.7% (77.2-94.5) was observed in samples with cycle threshold values ≤30. NowCheck COVID-19 Ag-RDT performed well at multiple healthcare facilities in an African field setting. Operational specificity and sensitivity were close to WHO-recommended thresholds.


Subject(s)
Antigens, Viral/analysis , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Nasopharynx/virology , Oropharynx/virology , SARS-CoV-2/immunology , Adult , Child , Cross-Sectional Studies , Developing Countries , Diagnostic Tests, Routine , Female , Humans , Kenya , Male , Middle Aged , Point-of-Care Testing , Prospective Studies , Sensitivity and Specificity